Skip to content

Frame grabber settings

Configuration file for Xcelera-CL+ PX8 framegrabber used in Splicer can be downloaded on Splicer Github Repository

This .ccf file is used by Teledyne DALSA's Sapera software to define how the Xcelera framegrabber communicates with a connected CameraLink Sensor. It configures timing, resolution, trigger modes, signal routing, and other acquisition parameters required for operation in Splicer.


Camera Configuration File Parameters

By opening the .ccf camera configuration file in the frame grabber software, all settings should be set correct for capture. For reference below an annotated list of the most important parameters.

Category Parameter Value Notes
Basic Timing Camera Type Linescan
Basic Timing Color Type Monochrome
Basic Timing Pixel Depth 8
Basic Timing Horizontal Active (in Pixels) 8192 This setting can be used to reduce active line length / resolution. This may be useful on lenses with smaller image circle
Basic Timing Horizontal Offset 0
Basic Timing Pixel Clock Input Frequency (MHz) 40
Basic Timing Data Valid Disabled
Basic Timing Camera Sensor Geometry Setting 2X2E-1Y
Basic Timing PoCL Disabled
Advanced Control Line Sync Source Shaft Encoder input If this is changed to internal line trigger, the following internal line trigger frequency becomes active and the sensor will capture an image without an external signal present. This can be ideal for debugging and during calibration
Advanced Control Internal Line Trigger Frequency (in Hz) 5000 (grayed out)
Advanced Control Camera Line Trigger Frequency Min (in Hz) 0
Advanced Control Camera Line Trigger Frequency Max (in Hz) 18600
Advanced Control Camera Control Method selected None
Advanced Control Line Integration Method Setting None
Advanced Control Line Trigger Method Setting None
Advanced Control Strobe Method Setting None
Advanced Control CC1 Pulse #1
Advanced Control CC2 Pulse #0
Advanced Control CC3 Not Used
Advanced Control CC4 Not Used
External Trigger External Trigger Enable
External Trigger External Trigger Detection Rising Edge
External Trigger External Trigger Level TTL
External Trigger External Trigger Source From External Trigger #1
External Trigger External Trigger Minimum Duration (in us) 0
External Trigger Frame Count per External Trigger 1
External Trigger External Trigger Delay 0
External Trigger External Trigger Delay Time Base Line Counts
External Trigger External Trigger Delay 0
External Trigger Shaft Encoder Source From Shaft Encoder Optocoupled
External Trigger Shaft Encoder Direction Ignored
External Trigger Shaft Encoder Edge Drop 0
External Trigger Shaft Encoder Edge Multiplier 1
External Trigger External Line Trigger Source Automatic
Image Buffer and ROI Image Width (in Pixels) 8192
Image Buffer and ROI Image Height (in Lines) 10000 This setting determines the length of the captured frame.
Image Buffer and ROI Image Left Offset (in Pixels) 0
Image Buffer and ROI Image Buffer Format Monochrome 8-bits
Image Buffer and ROI Image Flip Disabled
Image Buffer and ROI Acquisition Frame Length method Variable Length